IIT Madras Researchers Develop Ultrasound-based temperature tracking for Treatment Monitoring
Chennai: Indian Institute of Technology Madras Researchers have developed an Ultrasound-based temperature tracking for Treatment Monitoring. Unlike other imaging modalities, ultrasound combines several advantages such as safety (non-ionizing), real-time capability and portability, among others.
The IIT Madras Research Team was awarded the ‘SITARE – Gandhian Young Technological Innovation (GYTI) Appreciation 2020’ for this project.
This solution involves obtaining diagnostic ultrasound signals from the tissue region of interest inside the body, where heating is applied non-invasively from outside either through microwave applicator or High-intensity Focused ultrasound (HIFU), and process these signals, specifically, using prior knowledge from physics of wave interaction with the tissue medium.
Thermal Therapy using HIFU is already in use for treating solid tumours (both cancerous and benign). The current state-of-the-art technology monitors treatment using MRI (MR-guided HIFU). A popular clinical case is for treating Uterine Fibroids. The Technology developed by IIT Madras Researchers will be Ultrasound-based Monitoring, instead of MRI, thus making it accessible and affordable.
The Practical Benefits of this technology in the healthcare field include:
Ø Non-invasive treatment and real-time monitoring of the process
Ø Safe to use as no exposure to ionising radiation is involved
Ø Portable and suitable for point-of-care applications
Ø The ultrasound-based real-time feedback can be readily integrated with low-intensity ultrasound heat therapy devices that are commonly used in most physiotherapy centers
Hyperthermia, likewise, has shown promise for several ailments. Examples include using RF-electrode in liver disease treatment or disease of prostate. The IIT Madras Researchers contribution is to monitor this in real-time when, specifically, microwave is used. This combination makes it completely non-invasive and affordable. The results from these studies have been presented and published in various international IEEE society conferences over the last year.
Highlighting the advantages of this technology compared to existing technologies, Prof. Arun K. Thittai, Department of Applied Mechanics, IIT Madras, said, “Having multi-parametric image feedback allows for accurate real-time monitoring for a wide range of thermal therapies. These techniques can be incorporated as a software in existing scanners by the manufacturers and thus does not require any special electronics hardware.”
Currently, the IIT Madras researchers have demonstrated the feasibility of the methods using experiments done on tissue mimicking phantoms and ex-vivo tissue samples. They are now working to convert these proof-of-concept methods to design an integrated microwave applicator cum ultrasound-based real-time imaging feedback for a possible clinical application.
The Research Team involves faculty from the Department of Engineering Design at IIT Madras for the microwave applicator aspect. A complete in-house set up for HIFU ablation has been established by the researchers from Department of Applied Mechanic, IIT Madras.
Thermal (heat) therapy is used routinely for pain relief and rehabilitation of target tissue by inducing mild temperature elevation (<42°C) on them. Sufficient heating of target tissue inside the body (42°C-45°C: in hyperthermia; and >60°C in ablation) is also exploited as a treatment option for some disease, including ablation of cancerous tumor. However, one of the major challenges that prevents these approaches from wide-spread use in clinical practice is the lack of reliable and affordable real-time feedback in the form of heat maps from the targeted treatment region.
Although several ultrasound-based methods have been proposed in literature for temperature tracking, mostly for HIFU-ablation, maps of changes in other properties at different temperature realm have not been exploited. IIT Madras Researchers have the advantage of having access to complete signal chain of raw ultrasound data, and not just the final ultrasound image, that allows us to develop methods for tracking multiple different tissue parameter maps.
The List of Collaborators, partner institutes and funding agencies of this project include
Ø Dr. Kavitha Arunachalam, Associate Professor, Dept. of Engineering Design, IIT Madras
Ø Mr. Aliarshad Kothawala, PhD scholar, Dept. of Applied Mechanics, IIT Madras (recently joined Philips India after graduation)
Ø Ms. Divya Baskaran, PhD scholar, Dept. of Engineering Design, IIT Madras
Ø HIFU-Facility was established partly with funds from DST under FIST program
This research has been undertaken at the biomedical ultrasound laboratory at IIT Madras. Established in 2014, it is focussed on developing advanced, yet affordable, ultrasound imaging systems. They have filed for more than half a dozen technology patents in ultrasound imaging methods and devices in the last three years. A start-up has also been spun-off to develop ultrasound scanner with proprietary technology that offers advanced and state-of-the art features, yet is affordable.